136 research outputs found

    Localization of decorin gene expression in normal human breast tissue and in benign and malignant tumors of the human breast.

    Get PDF
    The small extracellular matrix proteoglycan decorin which possesses a potent antitumor activity has been shown to be present in various amounts in the stroma of several tumors including those of the breast. Regarding decorin in breast malignancies the published data are conflicting, i.e., whether breast cancer cells express it or not. Here, we first compared decorin gene expression levels between healthy human breast tissue and selected types of human breast cancer using GeneSapiens databank. Next, we localized decorin mRNA in tissue specimen of normal human breast, intraductal breast papillomas and various histologic types of human breast cancer using in situ hybridization (ISH) with digoxigenin-labeled RNA probes for decorin. We also examined the effect of decorin transduction on the behavior of cultured human breast cancer MCF7 cells. Analysis of GeneSapiens databank revealed that in various human breast cancers decorin expression is significant. However, ISH results clearly demonstrated that human breast cancer cells independently of the type of the cancer do not express decorin mRNA. This was also true for papilloma-forming cells of the human breast. Indeed, decorin gene expression in healthy human breast tissue as well as in benign and malignant tumors of human breast was shown to take place solely in cells of the original stroma. Decorin transduction using decorin adenoviral vector in decorin-negative MCF7 cells resulted in a significant decrease in the proliferation of these cells and changed cell cohesion. Decorin-transduced MCF7 cells also exhibited increased apoptosis. In conclusion, our study shows that in human breast tissue only cells of the original stroma are capable of decorin gene expression. Our study also shows that transduction of decorin in decorin-negative human breast cancer cells markedly modulates the growth pattern of these cells

    Effects of dexmedetomidine and MK-467 on plasma glucose, insulin and glucagon in a glibenclamide-induced canine hypoglycaemia model

    Get PDF
    The commonly used sedative α2-adrenoceptor agonist dexmedetomidine has adverse cardiovascular effects in dogs that can be prevented by concomitant administration of the peripherally acting α2-adrenoceptor antagonist MK-467. An ancillary effect of dexmedetomidine is to decrease insulin release from the pancreas, whereas MK-467 stimulates insulin release. This study assessed the effects of co-administered dexmedetomidine and MK-467 in a canine glibenclamide-induced hypoglycaemia model. In a randomised, cross-over experiment, eight beagle dogs received five intravenous treatments, comprising two administrations of saline, with dexmedetomidine or dexmedetomidine and MK-467, and three administrations of glibenclamide, with saline, dexmedetomidine or dexmedetomidine and MK-467. Plasma concentrations of glucose, lactate, insulin, glucagon and the test drugs were monitored. Administration of glibenclamide significantly increased insulin secretion and decreased blood glucose concentrations. Dexmedetomidine counteracted glibenclamide-evoked hypoglycaemia. This was opposed by the α2-adrenoceptor antagonist MK-467, but the glibenclamide-evoked hypoglycaemia was not potentiated by co-administration of dexmedetomidine and MK-467. None of the dogs developed uncontrolled hypoglycaemia. Thus, the combination of dexmedetomidine and MK-467 appeared to be safe in this canine hypoglycaemia model. Nevertheless, when MK-467 is used to alleviate the undesired cardiovascular effects of α2-adrenoceptor agonists in dogs, it should be used with caution in animals at risk for hypoglycaemia because of its insulin-releasing and hypoglycaemic effects.</p

    Increased Energy Expenditure, Lipolysis and Hyperinsulinemia Confer Resistance to Central Obesity and Type 2 Diabetes in Mice Lacking Alpha2α-Adrenoceptors

    Get PDF
    The α2A-adrenoceptors (ARs) are Gi-coupled receptors, which prejunctionally inhibit the release of norepinephrine (NE) and epinephrine (Epi), and postjunctionally insulin secretion and lipolysis. We have earlier shown that α2A-/- mice display sympathetic hyperactivity, hyperinsulinemia and improved glucose tolerance. Here we employed α2A-/- mice and placed the mice on a high-fat diet (HFD) to test the hypothesis that lack of α2A-ARs protects from diet-induced obesity (DIO) and type 2 diabetes (T2D). In addition, high caloric diet was combined with running wheel exercise to test the interaction of diet and exercise. HFD was obesogenic in both genotypes, but α2A-/- mice accumulated less visceral fat than their WT controls, were protected from T2D, and their insulin secretion was unaltered by the diet. Lack of α2A-ARs associated with increased sympatho-adrenal tone, which resulted in increased energy expenditure and fat oxidation rate potentiated by HFD. Fittingly, α2A-/- mice displayed enhanced lipolytic responses to Epi, and increased fecal lipids suggesting altered fat mobilization and absorption. Subcutaneous white fat appeared to be thermogenically more active (measured as Ucp1 mRNA expression) in α2A-/- mice, and brown fat showed an increased response to norepinephrine. Exercise was effective in reducing total body adiposity and increasing lean mass in both genotypes, but there was a significant diet-genotype interaction, as even modestly increased physical activity combined with lack of α2A-AR signalling promoted weight loss more efficiently than exercise with normal α2A-AR function. These results suggest that blockade of α2A-ARs may be exploited to reduce visceral fat and to improve insulin secretion.

    Transcatheter and surgical aortic valve replacement in patients with bicuspid aortic valve

    Get PDF
    Objectives: To compare the outcomes after surgical (SAVR) and transcatheter aortic valve replacement (TAVR) for severe stenosis of bicuspid aortic valve (BAV).Methods: We evaluated the early and mid-term outcome of patients with stenotic BAV who underwent SAVR or TAVR for aortic stenosis from the nationwide FinnValve registry.Results: The FinnValve registry included 6463 AS patients and 1023 (15.8%) of them had BAV. SAVR was performed in 920 patients and TAVR in 103 patients with BAV. In the overall series, device success after TAVR was comparable to SAVR (94.2% vs. 97.1%, p = 0.115). TAVR was associated with increased rate of mild-to-severe paravalvular regurgitation (PVR) (19.4% vs. 7.9%, p < 0.0001) and of moderate-to-severe PVR (2.9% vs. 0.7%, p = 0.053). When newer-generation TAVR devices were evaluated, mild-to-severe PVR (11.9% vs. 7.9%, p = 0.223) and moderate-to-severe PVR (0% vs. 0.7%, p = 1.000) were comparable to SAVR. Type 1 N-L and type 2 L-R/R-N were the BAV morphologies with higher incidence of mild-to-severe PVR (37.5% and 100%, adjusted for new-generation prostheses p = 0.025) compared to other types of BAVs. Among 75 propensity score-matched cohorts, 30-day mortality was 1.3% after TAVR and 5.3% after SAVR (p = 0.375), and 2-year mortality was 9.7% after TAVR and 18.7% after SAVR (p = 0.268) CONCLUSIONS: In patients with stenotic BAV, TAVR seems to achieve early and mid-term results comparable to SAVR. Type 1 N-L and type 2 L-R/R-N BAV morphologies had higher incidence of PVR. Larger studies evaluating different phenotypes of BAV are needed to confirm these findings.</p

    Brain Apolipoprotein E: an Important Regulator of Food Intake in Rats

    Get PDF
    OBJECTIVE—The worldwide prevalence of obesity is increasing at an alarming rate, along with the associated increased rates of type 2 diabetes, heart disease, and some cancers. While efforts to address environmental factors responsible for the recent epidemic must continue, investigation into the anorectic functions of potential molecules we present here, such as apolipoprotein (apo)E, offers exciting possibilities for future development of successful anti-obesity therapies

    Dedicated plug based closure for large bore access -The MARVEL prospective registry

    Get PDF
    Objectives To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. Background The MANTA is a novel plug-based device for large bore arteriotomy closure. Methods We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. Results Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 +/- 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. Conclusion In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.Peer reviewe

    Comparison of Outcomes After Transcatheter Aortic Valve Replacement vs Surgical Aortic Valve Replacement Among Patients With Aortic Stenosis at Low Operative Risk

    Get PDF
    Importance:  Transcatheter aortic valve replacement (TAVR) has been shown to be a valid alternative to surgical aortic valve replacement (SAVR) in patients at high operative risk with severe aortic stenosis (AS). However, the evidence of the benefits and harms of TAVR in patients at low operative risk is still scarce.Objective:  To compare the short-term and midterm outcomes after TAVR and SAVR in low-risk patients with AS.Design, Setting, and Participants:  This retrospective comparative effectiveness cohort study used data from the Nationwide Finnish Registry of Transcatheter and Surgical Aortic Valve Replacement for Aortic Valve Stenosis of patients at low operative risk who underwent TAVR or SAVR with a bioprosthesis for severe AS from January 1, 2008, to November 30, 2017. Low operative risk was defined as a Society of Thoracic Surgeons Predicted Risk of Mortality score less than 3% without other comorbidities of clinical relevance. One-to-one propensity score matching was performed to adjust for baseline covariates between the TAVR and SAVR cohorts.Exposures:  Primary TAVR or SAVR with a bioprosthesis for AS with or without associated coronary revascularization.Main Outcomes and Measures:  The primary outcomes were 30-day and 3-year survival.Results:  Overall, 2841 patients (mean [SD] age, 74.0 [6.2] years; 1560 [54.9%] men) fulfilled the inclusion criteria and were included in the analysis; TAVR was performed in 325 patients and SAVR in 2516 patients. Propensity score matching produced 304 pairs with similar baseline characteristics. Third-generation devices were used in 263 patients (86.5%) who underwent TAVR. Among these matched pairs, 30-day mortality was 1.3% after TAVR and 3.6% after SAVR (P = .12). Three-year survival was similar in the study cohorts (TAVR, 85.7%; SAVR, 87.7%; P = .45). Interaction tests found no differences in terms of 3-year survival between the study cohorts in patients younger than vs older than 80 years or in patients who received recent aortic valve prostheses vs those who did not.Conclusions and Relevance:  Transcatheter aortic valve replacement using mostly third-generation devices achieved similar short- and mid-term survival compared with SAVR in low-risk patients. Further studies are needed to assess the long-term durability of TAVR prostheses before extending their use to low-risk patients.</p

    Blood Transfusion and Outcome After Transfemoral Transcatheter Aortic Valve Replacement

    Get PDF
    Objective: To investigate the prognostic impact of red blood cell (RBC) transfusion on the outcome after transfemoral transcatheter aortic valve replacement (TAVR).Design: Nationwide, retrospective multicenter study.Setting: Five University Hospitals.Participants: The nationwide FinnValve registry included data from 2,130 patients who underwent TAVR for aortic stenosis from 2008 to 2017. After excluding patients who underwent TAVR through nontransfemoral accesses, 1,818 patients were selected for this analysis.Intervention: TAVR with or without coronary revascularization.Measurements and Main Results: RBCs were transfused in 293 patients (16.1%). Time-trend analysis showed that the rates of RBC transfusion decreased significantly from 27.5% in 2012 to 10.0% in 2017 (p Conclusions: Patients who received blood transfusion after TAVR had an increased risk of early and late adverse events. These adverse effects were particularly evident with increasing amount of RBC transfusion and operations for excessive bleeding.</p
    corecore